Description
Input liquid level transmitter LV60 is used for continuous static liquid level measurement. The water filling height of the ventilation tank can reach 2.5mWS to 25mWS (water column).
When the liquid level probe is immersed in liquid, a liquid column will appear above the probe. When the probe is immersed deep in the liquid, the liquid column will increase and generate hydrostatic pressure on the measuring system through its weight. The measured pressure is transmitted as a standard signal. The signal is proportional to the rising liquid.
The external pressure is identified by a special cable and an integrated pressure balancing hose. Automatically compensate for any change in air pressure and take into account the external pressure.
The level probe has been approved for use in potable water.